Modbus TCP OPC server

OPC Server for Modbus 3.0.0 New Release: What’s New in Our Modbus OPC Server

Quick answer: OPC Server for Modbus 3.0.0 is now available. This major update adds automatic Modbus block splitting, linear and square root scaling, network interface selection, clearer device diagnostics and an upgraded Modbus communication library, along with more than 30 fixes.

OPC Server for Modbus is a Modbus OPC server that connects Modbus TCP and serial devices, such as PLCs, RTUs and DCS, to any OPC DA client, including historians, HMIs and SCADA systems. Version 3.0.0 improves three things: how the server communicates with your devices, how you configure your tags and how you monitor your connections.

How the Modbus OPC server works

Modbus TCP OPC server architecture: PLC, RTU and DCS devices connected to historian, HMI and SCADA OPC DA clients
Figure 1. OPC Server for Modbus connects Modbus TCP and serial devices to OPC DA clients.

The server reads and writes data on your Modbus devices and exposes it as OPC tags, so any OPC DA client can exchange real-time data with them.

What’s new in version 3.0.0

Automatic Modbus block splitting

Reading registers in blocks is efficient: one request returns many values. The catch is that if one address in a block doesn’t exist on the device, the device rejects the whole request with an Illegal Data Address exception, and every tag in that block stops updating.

Version 3.0.0 handles this automatically. With Dynamic Block Resize enabled, the server subdivides the read block, isolates the invalid address range and keeps acquiring the valid addresses.

Modbus block splitting: an Illegal Data Address exception no longer stops a whole read block; valid addresses keep updating
Figure 2. With version 3.0.0, an Illegal Data Address exception isolates only the invalid range.

Linear and square root scaling

Modbus devices return raw values. Version 3.0.0 converts them into engineering units or application-specific ranges inside the server, so every OPC client receives the same ready-to-use values. Two methods are available:

  • Linear: maps a raw range to a scaled range in proportion.
  • Square root: applies a square root conversion, commonly used for flow measured with differential pressure transmitters.

Scaling can be disabled when raw values are required. The server also checks your settings: Raw Low must be smaller than Raw High, raw limits must match the raw data type, and scaled limits must fit the scaled data type. Scaling is unavailable for Coils, Discrete Inputs and Boolean or String data types. Each tag can now also carry a description and a unit.

Linear vs square root scaling in OPC Server for Modbus, converting raw Modbus values into engineering units
Figure 3. Linear and square root scaling convert raw Modbus values into engineering units.

Network interface selection

You can select the network interface used for Modbus TCP communications, or keep the default Windows network route. This gives you flexibility when the server host sits on several networks.

Clearer device diagnostics

New system tags report the communication status of each device. A new Check Device Status option helps you spot connection problems quickly.

System requirements and free trial

Item Requirement
.NET Framework 4.8 or higher
Operating system Windows 10, Windows 11, Windows Server 2016, 2019, 2022 or 2025
OPC specifications OPC Data Access 1.0a, 2.00, 2.05a and 3.0
Modbus protocols Modbus TCP and serial
  • Try it: start a 30-day free trial of OPC Server for Modbus.
  • Small projects: get a free license for up to 50 tags. Support fees are charged separately.
  • Already using an earlier version? Contact our team and we’ll walk you through upgrading to 3.0.0.

Moving your OPC hosts off Windows Server 2016? Read what OPC Classic users need to know before end of support.

Frequently asked questions

It's Modbus exception code 02. A device returns it when a request includes an address it doesn't support. In version 3.0.0, the server splits the read block automatically, so the valid addresses keep updating.

Yes. It connects to multiple Modbus TCP and serial devices, such as PLCs, RTUs and DCS.

Windows 10, Windows 11 and Windows Server 2016, 2019, 2022 and 2025, with .NET Framework 4.8 or higher.

Yes. You can start a 30-day free trial, or use a free license for up to 50 tags. Support fees are charged separately.

 